R.E.C. Roma – Official Rental Partner

Incandescent

Incandescent lamps are the oldest forms of production of artificial light. This form of production fixture, with the advent of sound recording in the film, was the only one allowed to approach the lighting within the scene without producing the annoying hum of the carbon produced by arcing predominantly used until then. Since the advent of sound on the development of lamps and lighting was continuous and unstoppable.
The luminous efficiency of the filament is linked to the materials used to make the lamp, while the light source colour and durability are closely related to the amount of electricity and depending on the resistance of the filament. Only a maximum of 10% of the current used produces the effect radiant light, the remaining 90% will only produce thermal radiation.

With the voltage growth, the filament increases efficiency and colour temperature, but because of faster tungsten evaporation which it is composed, the overall duration of the lamp is reduced exponentially.

The tungsten evaporation deposited on the wall of glass bulb, in the case of high absorption lamp for large projectors it will produce a blackening with a lower colour temperature. This colour decay, reduced the operational life suitable for the shots. In recent years, to use the technology of incandescent bulb lamps were produced in “hard glass” that ensured smaller bulb size allowing equal dispersion of caloric radiation, the smaller projector size lighting and a longer service life.

Watt Volt Connection Brand Name Kelvin Life Code
15 230 E 27 Philips Darkroom PF710 E Yellow Green - 1000 PF710 E
15 230 E 27 Philips Darkroom PF712 E Red - 1000 PF712 E
75 230 E 27 Philips PF603 E Internal White 2800 100 PF603 E/51
150 220 E 27 Philips PF319 E Refl Sat Frost 3200 100 PF319 E/44
150 230 E 27 Philips PF605 E Internal White 2800 100 PF605 E/51
250 230 E 27 Philips PF207 E Ins Frosted 3400 3 PF207 E/21
250 230 E 27 Philips PF607 E Internal White 3000 3 PF607 E/51
500 220 E 27 Philips PF208 E Ins Frosted 3400 6 PF208 E/21
500 220 E 27 Philips PF308 E Ins Frosted 3200 100 PF308 E/21
500 220 E 27 Philips PF318 E Refl Sar Frost 3200 100 PF318 E/44
No matching results found.

Halogen

In the late 50's the evolution of the lamp concept of a bulb with tungsten filament is introduced. Lamps popularly called Quartz - Halogen Iodine were born.

The Structure:

In a quartz bulb is placed a tungsten filament in the presence of iodine gas. This gas has proved to be suitable to create a chemical reaction that turns the tungsten, evaporated by the incandescence, produced by the current flow, into solid particles that will be deposited on the filament avoiding to blacken the bulb and allowing a more natural life and a more constant light output.

Technical Features:

The regeneration phenomenon said “halogen cycle” needs, however, that every part of the lamp will maintain a constant temperature of 250 ° C. The quartz cruet does its part by allowing to maintain the gas high pressure introduced and preventing by its hardness, that would produce anomalous swellings at that point causing a temperature lowering that would stop the cycle. The compactness of the lamp resulting from this technology allowed to obtain luminous efficiency much higher than normal incandescent technology, constant colour temperature for a longer period of exercise and life, in proportion to the flows certainly longer. The small size of the bulbs have allowed to the projectors to reach lightness and compactness, since then impossible. The advent of the bulbs with halogen bulbs used in other evacuated glass has further improved data efficiency and durability, making today one of the most economic and accessible systems even if energy costs do not fully adapted to the times.

Watt Volt Connection Brand Name Kelvin Life Code
30 6,4 con viti GE Par 36 Screw Terminal CAP 4515 - 100 24673
30 6,4 con viti GE Par 36 Screw Terminal CAP H4515 - 100 15133
30 6,4 con viti GE Par 36 Screw Terminal CAP H7604 - 100 43576
30 6,4 con viti GE Par 46 Screw Terminal CAP 4535 - 100 24735
30 12,8 con viti GE Par 46 Screw Terminal CAP 4435 - 300 24577
50 12 con viti GE Par 36 Screw Terminal CAP NSP - 2000 16540
50 12 con viti GE Par 36 Screw Terminal CAP VNSP - 2000 12892
50 12 con viti GE Par 36 Screw Terminal CAP WFL - 2000 16541
50 12 G 6,35 PHILIPS Single Ended Specialist Proj. 3300 50 7027
50 12 G 6,35 GE Single Ended Specialist Proj. A1/220 3400 50 18234
No matching results found.

Dicharge Bulbs HMI

The dicharge bulbs or HMI, compared to the Incandescent bulbs, the light is generated through a dicharge arch. Special gas fill the cruet joining a color temperature between 5600K and 6000K. The HMI bulbs contains the right combination of haloids of different metals and rare earths like dysprosium, Omio and Thulium, in addition to mercury vapors. From these components was born its name: H is the abbreviation for mercury (Hg), that is mainly used to obtain bulb power that has to be high enough. M is for the metal presence that give the typical effect of the daylight. I is for the addition of a mixed halogenated components (ioduri and bromides) necessary for different functions. The known halogen cyclic process - tungsten in the incandescent and halogens bulbs prevents the tungsten particles, blowing away from the electrodes, will deposit on the inner wall of the bulb. Other cyclic processes make sure that in the hot zone of the arc a high concentration of metals vapors and rare earths will be reached, to produce light.

The structure

The HMI lamp is made in high temperature resistant quartz. Two tungsten electrodes are positioned axially inside a discharge tube that has a cylindrical or ellipsoidal shape. The electricity flow happens through molybdenum sheets very thin, dipped in quartz inside the bulb to keep the gas and they are the electrical link between the base and the discharge tube electrodes.

Light beam and light efficiency

The HMI bulbs offer a light efficiency 3 - 4 times superior then Halogen bulbs of the same power. They require an UV absorbing glass, that come from the lens of Fresnel projectors or from the protection lens of some bulbs included in parabolic systems.

Technical features

To start the discharge process in the gas of these bulbs, a high power ignition is necessary. In this phase the start up will require one second maximum and will be sufficient high power impulses but low Kv. In case of hot restart on high power impulse lighters are necessary to ionize the zone between the electrodes: from 20 to 70Kv are required depending on the bulb power type. Once the cold restart is on, the filling materials (mercury, haloids, rare earth) evaporate in 1 - 3 minutes. At the same time gradually increase the bulb power, the electrical power and the luminous flow until the nominal value will be reached. Color temperature and bulb wattage are higher at the beginning compared to the time while the bulb joined it’s light stability. The color temperature changes, are very relevant at the beginning until the bulb will join the correct one, and they may cause a trick for uncareful users. The use of a Thermocolorimeter can be useful to measure possible differences between lamps new and just used, if mounted on the same projectors.

Watt Volt Connection Brand Name Kelvin Life Code
125 80 GZX 9,5 GE HR Single Ended CSR125/SE/HR 5600 200 48461
125 207 GZX 9,5 PHILIPS HR Single Ended MSR125/HR 6000 200 HRMSR125
150 95 GY 9,5 OSRAM Cold Start HTI152W 5000 2000 HTI152W
152 95 GY 9,5 GE Cold Start CSR152/SE 5000 750 22862
200 70 GY 9,5 OSRAM Cold Start HSD200/60 6000 2000 HSD200/60
200 70 GZY 9,5 GE HR Single Ended CSR200/SE/HR 5600 200 48462
200 70 GZY 9,5 OSRAM HR Single Ended HMI200W/SE 6000 200 HMI200W/SE
200 80 X 515 GE HR Double Ended CSR200/DE 6000 300 48450
200 207 GY 9,5 PHILIPS Cold Start (MSD) MSD200 6000 2000 MSD200
200 207 GZY 9,5 PHILIPS HR Single Ended MSR200/HR 6000 200 HRMSR200
200 60/- SFC 10-4 OSRAM HR Double Ended SharXS HTI200W/D3/70 7000 3000 HTI200W/D3/70
No matching results found.

Fluorescent

The Fluorescent light obtained its consideration in the photography, cinematography and television fields. The low source required, the low hot temperature emission, and the bulb light spectrum stability contribute to make this bulb successful. This kind of light, at non continuous spectrum, belong today to almost all indoor environments both private and industrial. Fluorescent tubes for cinematography have stability chromaticity and light bundle different from the same bulbs used for indoors or industrial environments, but for the principle their made of, they all keep a high level of radiations in some zones of the spectrum.

The structure
The base principle is that of supplying the light through substances hit by a flow of photons. These bulbs are made by a tube of hard glass that contains low pressure mercury vapors with a small gas quantity required to catalyze the tube. The voltaic arc that comes out from the two electrodes excites the fluorescence.

Technical features
In the family of bulbs that generates white light the bulbs are selected depending on the color temperature required in photography, cinematography and television. The lamps require an electronic system able to produce discharge sequence that will allow to eliminate the “flicker” that may occur. The maximum light efficiency and spectrum and chromatic stability, is reached soon after the start up, but may change if the microclima condition around the tubes is modified due to the presence of filters or any other accessory that increase the thermal concentration along the tube.

Watt Connection Brand Name Kelvin Life Code
6 G5 BIPIN KINOFLO Cinema F6T5 - KF29 - L. 212 mm 2900 - 092-K29
6 G5 BIPIN KINOFLO Cinema F6T5 - KF55 - L. 212 mm 5500 - 092-K55
8 G5 BIPIN KINOFLO Cinema F8T5 - KF29 - L. 305 mm 2900 - 122-K29
8 G5 BIPIN KINOFLO Cinema F8T5 - KF55 - L. 305 mm 5500 - 122-K55
17 G13 GE F17T8/Cinema32 - L. 600 mm 3200 15000 15724
17 G13 GE F17T8/Cinema55 - L. 600 mm 5500 15000 15725
18 G13 OSRAM Lumilux - Biolux 18/965 - L. 600 mm 6500 - Lumilux L 18W/965
18 G13 OSRAM Lumilux - L 18/930 - L. 600 mm 3000 - Lumilux L 18W/930
18 G13 OSRAM Lumilux - L 18/940 - L. 600 mm 4000 - Lumilux L 18W/940
18 G13 OSRAM Lumilux - L 18/954 - L. 600 mm 5400 - Lumilux L 18W/954
18 G13 OSRAM Wood Light L18/73 - 0,37 A - L. 590 mm - - L 18/73
No matching results found.

Specials

Infrared Lamps

These are lamps that, thanks to infrared technology, can be applied in a wide range of industrial sectors from heating to drying, from curing to catering, and specifically in: zone heating, infrared cabins, etc.

Read more

Germicida TUV Series

These are lamps that use ultraviolet radiation (253.7 nm) to destroy bacteria, viruses and other primitive organisms. They are used for cleaning and disinfecting air, water (swimming pools) and surfaces.

Read more

Germicida TUV PL-L e PL-S Series

These are lamps that maintain the ecosystem balance in garden ponds, keeping the water crystal clear, preventing the growth of germs, and above all not harming the fish and plants in the pond.

Read more

10UV-A Series

These are lamps that maintain the ecosystem balance in garden ponds, keeping the water crystal clear, preventing the growth of germs, and above all not harming the fish and plants in the pond.

Read more

Super Actinic Colour / 03

They have a spectrum suited for Diazo copier lamps for graphic arts, for phototherapy in the treatment of jaundice in newborns (under medical supervision), and in aquarium keeping to recreate the perfect environment in marine aquariums.

Read more

Colours Lamps

These are coloured lamps used to light venues such as bars, dance halls and events where a colourful, lively atmosphere is needed. They are also effective in certain specific industrial applications.

Read more

Aquarelle Lamps

Lamps for use in freshwater aquariums. Combined with TL D/80 New Generation and/or TL D/90 De Luxe lamps, they provide excellent brightness without disturbing the aquarium's biological balance.

Read more

UV Discharge HOK

They are used in various industrial processes such as curing, drying of lacquers, inks and paints, and various photochemical reactions. They can also be installed in large water/air sterilisation systems, etc.

Read more

Medical and Therapy

The /01 and /12 lamps are used to treat psoriasis and other skin conditions, the /12 lamps are also used in meteorology, while the /52 lamps are used to treat neonatal jaundice.

Read more

CLEO series bronzers

Piercings, tattoos and lingerie merely accentuate beauty which is already there. As you know, the essential part of beauty is a gorgeous skin. Philips CLEO offers a great variety of tanning lamps for different skin types and different purposes.

Read more